HP iLO
HP iLO Event Monitor
The HP iLO Event Monitor monitors fans, power supplies, and temperatures.
notitie
Overview
The HP iLO Event Monitor connects to the "Integrated Lights Out" system found on many systems sold by Hewlett Packard. iLO provides hardware-related data about a system, including details about fans, temperatures, and power supplies.
info
Use Cases
- Monitoring the hardware health status of your Dell servers
- Alerting based on high power consumption
- Notifying about battery status and temperature
Monitoring Options
This event monitor provides the following options:
- HP iLO Version: Select the version of iLO on the systems to be monitored.
- Alert with [Info/Warning/Error/Critical] if the HP iLO server is unreachable: Get alerts if the iLO system could not be contacted.
- Alert with [Info/Warning/Error/Critical] if chassis health status is not OK: Get alerts about any alarms related to the system chassis.
- Alert with [Info/Warning/Error/Critical] if chassis power supply health status is not OK: Alert about power supplies and their status.
- Alert with [Info/Warning/Error/Critical] if fan health status is not OK: Get alerts related to fans and their speeds.
- Alert with [Info/Warning/Error/Critical] if temperature probe health status is not OK: Get alerts about the availability of temperature probes on the system.
- Alert with [Info/Warning/Error/Critical] if system health status is not OK: Get alerts about the general health of the system.
- Alert with [Info/Warning/Error/Critical] if array controller health status is not OK: Alert about array controllers and their status.
- Alert with [Info/Warning/Error/Critical] if logical drive health status is not OK: Check the status of all logical drives and alert if any are not OK.
- Alert with [Info/Warning/Error/Critical] if disk drive health status is not OK: Check the status of all physical drives and alert if any are not OK.
- Alert with [Info/Warning/Error/Critical] if a temperature probe is greater than its threshold: Get temperature alerts for critical and non-critical levels as defined by the iLO system settings.
- Alert if the temperature of a disk drive is more than the specified thresholds: Check the temperature of physical disks and alert if it exceeds specified thresholds.
- Alert with [Info/Warning/Error/Critical] if array controller backup power status is not OK: Alert about backup power status for array controllers.
- Alert with [Info/Warning/Error/Critical] if the available power for a chassis is less than specified thresholds: Set alerts about power availability for the chassis.
- Alert with [Info/Warning/Error/Critical] if the average consumed power for a chassis is greater than specified thresholds: Set thresholds based on power consumption for the chassis.
- Alert if a fan's speed is running greater than specified speeds: Check fan speeds and alert based on specified values.
Authentication and Security
The account used for authentication must be able to access the iLO interface.
Protocols
Data Points
Data Point | Description |
---|---|
Available Power | The power available to your devices. |
Consumed Power | The total power consumed by your devices. |
Average Consumed Power | The average amount of power consumed by your devices. |
Fan Speed | The detected speed of your fans. |
Temperature | The temperature of your devices. |